A packaged unit contains the condenser, coil, blower and heat source in a single outdoor cabinet. Ductwork connects directly to the unit, so no indoor equipment space is required.

Showing all 13 results

Ruud RGEAYB024AJT061N 2 Ton 13.4 SEER2 Packaged Gas/Electric Unit

$4,137.33
All components in a single outdoor cabinet for homes of roughly 900–1,200 sq ft — no indoor furnace or coil to house, and ductwork connects directly to the unit. Suits slab-on-grade homes and light commercial rooftops. 208/230V, 1 Phase, 60 Hz.

Ruud RGEAYB030AJT081N 2.5 Ton 13.4 SEER2 Packaged Gas/Electric Unit

$4,665.33
All components in a single outdoor cabinet for homes of roughly 1,200–1,400 sq ft — no indoor furnace or coil to house, and ductwork connects directly to the unit. Suits slab-on-grade homes and light commercial rooftops. 208/230V, 1 Phase, 60 Hz.

Ruud RGEAYB036AJT081N 3 Ton 13.4 SEER2 Packaged Gas/Electric Unit

$4,765.33
All components in a single outdoor cabinet for homes of roughly 1,400–1,700 sq ft — no indoor furnace or coil to house, and ductwork connects directly to the unit. Suits slab-on-grade homes and light commercial rooftops. 208/230V, 1 Phase, 60 Hz.

Ruud RGEAYB042AJT101N 3.5 Ton 13.4 SEER2 Packaged Gas/Electric Unit

$5,732.00
All components in a single outdoor cabinet for homes of roughly 1,700–2,000 sq ft — no indoor furnace or coil to house, and ductwork connects directly to the unit. Suits slab-on-grade homes and light commercial rooftops. 208/230V, 1 Phase, 60 Hz.

Ruud RGEAYB048AJT101N 4 Ton 13.4 SEER2 Packaged Gas/Electric Unit

$5,956.00
All components in a single outdoor cabinet for homes of roughly 2,000–2,400 sq ft — no indoor furnace or coil to house, and ductwork connects directly to the unit. Suits slab-on-grade homes and light commercial rooftops. 208/230V, 1 Phase, 60 Hz.

Ruud RGEAYB060AJT101N 5 Ton 13.4 SEER2 Packaged Gas/Electric Unit

$6,033.33
All components in a single outdoor cabinet for homes of roughly 2,400–3,000 sq ft — no indoor furnace or coil to house, and ductwork connects directly to the unit. Suits slab-on-grade homes and light commercial rooftops. 208/230V, 1 Phase, 60 Hz.

Ruud RHPAYB024AJT101N 2 Ton 13.4 SEER2 Packaged Heat Pump

$4,638.67
All components in a single outdoor cabinet for homes of roughly 900–1,200 sq ft — no indoor furnace or coil to house, and ductwork connects directly to the unit. Suits slab-on-grade homes and light commercial rooftops.

Ruud RHPAYB030AJT101N 2.5 Ton 13.4 SEER2 Packaged Heat Pump

$4,806.67
All components in a single outdoor cabinet for homes of roughly 1,200–1,400 sq ft — no indoor furnace or coil to house, and ductwork connects directly to the unit. Suits slab-on-grade homes and light commercial rooftops.

Ruud RHPXYB036AJT101N 3 Ton 13.4 SEER2 Packaged Heat Pump

$4,938.67
All components in a single outdoor cabinet for homes of roughly 1,400–1,700 sq ft — no indoor furnace or coil to house, and ductwork connects directly to the unit. Suits slab-on-grade homes and light commercial rooftops.

Ruud RHPXYB036AJT151N 3 Ton 13.4 SEER2 Packaged Heat Pump

$5,116.00
All components in a single outdoor cabinet for homes of roughly 1,400–1,700 sq ft — no indoor furnace or coil to house, and ductwork connects directly to the unit. Suits slab-on-grade homes and light commercial rooftops.

Ruud RHPXYB042AJT151N 3.5 Ton 13.4 SEER2 Packaged Heat Pump

$5,598.67
All components in a single outdoor cabinet for homes of roughly 1,700–2,000 sq ft — no indoor furnace or coil to house, and ductwork connects directly to the unit. Suits slab-on-grade homes and light commercial rooftops.

Ruud RHPXYB048AJT151N 4 Ton 13.4 SEER2 Packaged Heat Pump

$5,800.00
All components in a single outdoor cabinet for homes of roughly 2,000–2,400 sq ft — no indoor furnace or coil to house, and ductwork connects directly to the unit. Suits slab-on-grade homes and light commercial rooftops.

Ruud RHPXYB060AJT151N 5 Ton 13.4 SEER2 Packaged Heat Pump

$6,424.00
All components in a single outdoor cabinet for homes of roughly 2,400–3,000 sq ft — no indoor furnace or coil to house, and ductwork connects directly to the unit. Suits slab-on-grade homes and light commercial rooftops.

Where packaged units suit

Slab-on-grade homes with no basement or attic, manufactured housing, and light commercial rooftops — anywhere there is no practical space for an indoor furnace and coil. They are also simpler to service, since all components are accessible from one location.

No component matching required

Because the unit ships as a single factory assembly, the AHRI certificate covers the complete product. There is no coil to match, no furnace to select, and no risk of an uncertified pairing. The certificate number is listed on every product page.

Gas/electric or heat pump

Gas/electric units cool electrically and heat with gas, and need a gas connection at the unit. Packaged heat pumps do both electrically with no gas at all. Both use R-454B refrigerant and both require a suitable pad or curb and a duct connection at the cabinet.