Outdoor heat pumps that provide both heating and cooling from one unit, with no gas supply or combustion venting required. Pair with an air handler for all-electric, or a gas furnace for dual fuel.

Showing 1–24 of 26 results

Ruud RD16AY24AJVC 2 Ton 16.0 SEER2 Heat Pump

$3,801.60
Ruud RD16AY24AJVC: two stage outdoor heat pump (rough sizing guide: 900–1,200 sq ft). Pair with an air handler and heat kit for an all-electric system, or a gas furnace for dual fuel. R-454B refrigerant, 208/230V, 1 Phase, 60 Hz. Cabinet 31.8" x 19.8" x 40.4".

Ruud RD16AY36AJVC 3 Ton 16.0 SEER2 Heat Pump

$4,002.56
Ruud RD16AY36AJVC: two stage outdoor heat pump (rough sizing guide: 1,400–1,700 sq ft). Pair with an air handler and heat kit for an all-electric system, or a gas furnace for dual fuel. R-454B refrigerant, 208/230V, 1 Phase, 60 Hz. Cabinet 31.8" x 19.8" x 40.4".

Ruud RD16AY48AJVC 4 Ton 16.0 SEER2 Heat Pump

$4,725.76
Ruud RD16AY48AJVC: two stage outdoor heat pump (rough sizing guide: 2,000–2,400 sq ft). Pair with an air handler and heat kit for an all-electric system, or a gas furnace for dual fuel. R-454B refrigerant, 208/230V, 1 Phase, 60 Hz. Cabinet 36.6" x 19.8" x 40.4".

Ruud RD16AY60AJVC 5 Ton 16.0 SEER2 Heat Pump

$4,975.36
Ruud RD16AY60AJVC: two stage outdoor heat pump (rough sizing guide: 2,400–3,000 sq ft). Pair with an air handler and heat kit for an all-electric system, or a gas furnace for dual fuel. R-454B refrigerant, 208/230V, 1 Phase, 60 Hz. Cabinet 46.4" x 22.8" x 42.3".

Ruud RD18AY24AJVC 2 Ton 18.0 SEER2 Heat Pump

$4,391.68
Ruud RD18AY24AJVC: variable speed outdoor heat pump (rough sizing guide: 900–1,200 sq ft). Pair with an air handler and heat kit for an all-electric system, or a gas furnace for dual fuel. R-454B refrigerant, 208/230V, 1 Phase, 60 Hz. Cabinet 36.6" x 19.8" x 40.4".

Ruud RD18AY36AJVC 3 Ton 18.0 SEER2 Heat Pump

$4,622.08
Ruud RD18AY36AJVC: variable speed outdoor heat pump (rough sizing guide: 1,400–1,700 sq ft). Pair with an air handler and heat kit for an all-electric system, or a gas furnace for dual fuel. R-454B refrigerant, 208/230V, 1 Phase, 60 Hz. Cabinet 46.4" x 22.8" x 42.3".

Ruud RD18AY48AJVC 4 Ton 18.0 SEER2 Heat Pump

$5,456.64
Ruud RD18AY48AJVC: variable speed outdoor heat pump (rough sizing guide: 2,000–2,400 sq ft). Pair with an air handler and heat kit for an all-electric system, or a gas furnace for dual fuel. R-454B refrigerant, 208/230V, 1 Phase, 60 Hz. Cabinet 58" x 19.8" x 40.4".

Ruud RD18AY60AJVC 5 Ton 18.0 SEER2 Heat Pump

$5,745.92
Ruud RD18AY60AJVC: variable speed outdoor heat pump (rough sizing guide: 2,400–3,000 sq ft). Pair with an air handler and heat kit for an all-electric system, or a gas furnace for dual fuel. R-454B refrigerant, 208/230V, 1 Phase, 60 Hz. Cabinet 58" x 19.8" x 40.4".

Ruud RP14AY18AJ1N 1.5 Ton 14.3 SEER2 Heat Pump

$1,355.52
Ruud RP14AY18AJ1N: single stage outdoor heat pump (rough sizing guide: 600–900 sq ft). Pair with an air handler and heat kit for an all-electric system, or a gas furnace for dual fuel. R-454B refrigerant, 208/230V, 1 Phase, 60 Hz. Cabinet 25" x 29.75" x 29.75".

Ruud RP14AY24AJ2N 2 Ton 14.3 SEER2 Heat Pump

$1,440.00
Ruud RP14AY24AJ2N: two stage outdoor heat pump (rough sizing guide: 900–1,200 sq ft). Pair with an air handler and heat kit for an all-electric system, or a gas furnace for dual fuel. R-454B refrigerant, 208/230V, 1 Phase, 60 Hz. Cabinet 25" x 29.75" x 29.75".

Ruud RP14AY30AJ2N 2.5 Ton 14.3 SEER2 Heat Pump

$1,694.72
Ruud RP14AY30AJ2N: two stage outdoor heat pump (rough sizing guide: 1,200–1,400 sq ft). Pair with an air handler and heat kit for an all-electric system, or a gas furnace for dual fuel. R-454B refrigerant, 208/230V, 1 Phase, 60 Hz. Cabinet 27" x 33.75" x 33.75".

Ruud RP14AY36AJ2N 3 Ton 14.3 SEER2 Heat Pump

$1,793.28
Ruud RP14AY36AJ2N: two stage outdoor heat pump (rough sizing guide: 1,400–1,700 sq ft). Pair with an air handler and heat kit for an all-electric system, or a gas furnace for dual fuel. R-454B refrigerant, 208/230V, 1 Phase, 60 Hz. Cabinet 35" x 33.75" x 33.75".

Ruud RP14AY42AJ2N 3.5 Ton 14.3 SEER2 Heat Pump

$2,064.64
Ruud RP14AY42AJ2N: two stage outdoor heat pump (rough sizing guide: 1,700–2,000 sq ft). Pair with an air handler and heat kit for an all-electric system, or a gas furnace for dual fuel. R-454B refrigerant, 208/230V, 1 Phase, 60 Hz. Cabinet 35" x 33.75" x 33.75".

Ruud RP14AY48AJ2N 4 Ton 14.3 SEER2 Heat Pump

$2,237.44
Ruud RP14AY48AJ2N: two stage outdoor heat pump (rough sizing guide: 2,000–2,400 sq ft). Pair with an air handler and heat kit for an all-electric system, or a gas furnace for dual fuel. R-454B refrigerant, 208/230V, 1 Phase, 60 Hz. Cabinet 35" x 33.75" x 33.75".

Ruud RP14AY60AJ2N 5 Ton 14.3 SEER2 Heat Pump

$2,836.48
Ruud RP14AY60AJ2N: two stage outdoor heat pump (rough sizing guide: 2,400–3,000 sq ft). Pair with an air handler and heat kit for an all-electric system, or a gas furnace for dual fuel. R-454B refrigerant, 208/230V, 1 Phase, 60 Hz. Cabinet 39" x 35.75" x 35.75".

Ruud RP15AY18AJ2N 1.5 Ton 15.2 SEER2 Heat Pump

$2,786.56
Ruud RP15AY18AJ2N: two stage outdoor heat pump (rough sizing guide: 600–900 sq ft). Pair with an air handler and heat kit for an all-electric system, or a gas furnace for dual fuel. R-454B refrigerant, 208/230V, 1 Phase, 60 Hz. Cabinet 25" x 29.75" x 29.75".

Ruud RP15AY24AJ2N 2 Ton 15.2 SEER2 Heat Pump

$2,958.08
Ruud RP15AY24AJ2N: two stage outdoor heat pump (rough sizing guide: 900–1,200 sq ft). Pair with an air handler and heat kit for an all-electric system, or a gas furnace for dual fuel. R-454B refrigerant, 208/230V, 1 Phase, 60 Hz. Cabinet 25" x 29.75" x 29.75".

Ruud RP15AY30AJ2N 2.5 Ton 15.2 SEER2 Heat Pump

$3,171.84
Ruud RP15AY30AJ2N: two stage outdoor heat pump (rough sizing guide: 1,200–1,400 sq ft). Pair with an air handler and heat kit for an all-electric system, or a gas furnace for dual fuel. R-454B refrigerant, 208/230V, 1 Phase, 60 Hz. Cabinet 35" x 33.75" x 33.75".

Ruud RP15AY36AJ2N 3 Ton 15.2 SEER2 Heat Pump

$3,554.56
Ruud RP15AY36AJ2N: two stage outdoor heat pump (rough sizing guide: 1,400–1,700 sq ft). Pair with an air handler and heat kit for an all-electric system, or a gas furnace for dual fuel. R-454B refrigerant, 208/230V, 1 Phase, 60 Hz. Cabinet 39" x 35.75" x 35.75".

Ruud RP15AY42AJ2N 3.5 Ton 15.2 SEER2 Heat Pump

$3,869.44
Ruud RP15AY42AJ2N: two stage outdoor heat pump (rough sizing guide: 1,700–2,000 sq ft). Pair with an air handler and heat kit for an all-electric system, or a gas furnace for dual fuel. R-454B refrigerant, 208/230V, 1 Phase, 60 Hz. Cabinet 39" x 35.75" x 35.75".

Ruud RP15AY48AJ2N 4 Ton 15.2 SEER2 Heat Pump

$3,980.80
Ruud RP15AY48AJ2N: two stage outdoor heat pump (rough sizing guide: 2,000–2,400 sq ft). Pair with an air handler and heat kit for an all-electric system, or a gas furnace for dual fuel. R-454B refrigerant, 208/230V, 1 Phase, 60 Hz. Cabinet 39" x 35.75" x 35.75".

Ruud RP15AY60AJ2N 5 Ton 15.2 SEER2 Heat Pump

$4,430.08
Ruud RP15AY60AJ2N: two stage outdoor heat pump (rough sizing guide: 2,400–3,000 sq ft). Pair with an air handler and heat kit for an all-electric system, or a gas furnace for dual fuel. R-454B refrigerant, 208/230V, 1 Phase, 60 Hz. Cabinet 39" x 35.75" x 35.75".

Ruud UP19AY24AJVC 2 Ton 19.0 SEER2 Heat Pump

$7,171.84
Ruud UP19AY24AJVC: variable speed outdoor heat pump (rough sizing guide: 900–1,200 sq ft). Pair with an air handler and heat kit for an all-electric system, or a gas furnace for dual fuel. R-454B refrigerant, 208/230V, 1 Phase, 60 Hz. Cabinet 45.17" x 36.13" x 36.13".

Ruud UP19AY36AJVC 3 Ton 19.0 SEER2 Heat Pump

$7,808.00
Ruud UP19AY36AJVC: variable speed outdoor heat pump (rough sizing guide: 1,400–1,700 sq ft). Pair with an air handler and heat kit for an all-electric system, or a gas furnace for dual fuel. R-454B refrigerant, 208/230V, 1 Phase, 60 Hz. Cabinet 51.17" x 36.13" x 36.13".

Two ways to configure a heat pump

Paired with an air handler and heat strip kit you get an all-electric system with no gas connection at all. Paired with a gas furnace you get a dual fuel system that switches to gas heat in the coldest weather. Both configurations must use AHRI-certified component matches.

Side-discharge models

The RD16AY and RD18AY series discharge air sideways rather than upward, which lets them sit closer to a wall and under overhangs where a conventional top-discharge unit will not fit. Useful on tight lots and in zero-lot-line developments.

Panel capacity

Heat pumps draw more electrical load than cooling-only equipment, and supplemental heat adds more again. Confirm your service capacity before ordering rather than discovering the problem on installation day.